Level 1 sweep and inspection to the NFPA 211 annual standard - flue, crown, cap, and flashing checked and photographed
Chimney sweep logs do not sweep chimneys. They loosen some creosote - which then falls where a brush and vacuum still have to collect it.
DuraFlex Flue Liner Replacement: The Boulder Owner’s Guide
DuraFlex flue liner replacement in Boulder typically runs $2,800-$4,500 installed, depending on chimney height, diameter, and whether the existing top plate and connector need replacement alongside the liner itself. We stock DuraFlex-compatible flue liner in 3-, 4-, 5-, 6-, 7-, and 8-inch diameters on our trucks, and most replacements in Boulder, Mapleton Hill, and Chautauqua are completed in a single day. Most owners discover the liner has failed during a routine sweep when the camera reveals cracked seams, corrosion pinholes, or separation at the collar - often after smelling smoke in the house or noticing drafting problems on still, cold mornings.
Which DuraFlex Models This Applies To
DuraFlex produces several liner series, and the replacement protocol differs materially between them. The DuraFlex SW (smooth wall) and DuraFlex HT (high temperature) are the two we encounter most often in Boulder homes, particularly in wood-burning systems built between 1990 and 2015. The SW series carries a .005-inch wall thickness with a 316Ti stainless core; the HT steps up to .006-inch with an aluminized outer layer for higher heat duty. You can identify your series by the stamped collar label at the top termination, or by measuring wall thickness with a caliper at a cleanout opening.
Here’s where owners get tripped up: DuraFlex uses proprietary collar geometry on its SW series that does not mate cleanly with generic flex adapters. We’ve seen Boulder homeowners buy aftermarket liner that fits the flue diameter but leaves a 3/8-inch gap at the collar that leaks condensation and stains the masonry. We source DuraFlex OEM through Haven’s buying network, along with verified-compatible aftermarket from Olympia Chimney and Copperfield when the job calls for it. HeatShield and Gelco are also in our stock for partial relining or joint repair when full replacement isn’t necessary. Corrine Halstead checks every collar fit personally before the crew loads the truck - “The camera doesn’t guess. Neither do I.”
Signs Your DuraFlex Flue Liner Replacement Is Failing

- Smoke odor in living spaces on startup. This usually means the liner has developed a longitudinal split or seam separation, allowing exhaust to bypass the flue and enter the chimney cavity. In Boulder’s dry climate, thermal cycling from near-zero mornings to 500°F firebox temperatures accelerates this fatigue.
- Visible rust streaks on the exterior masonry. DuraFlex liners are stainless, but the top plate, storm collar, and termination hardware are galvanized or aluminum - when these corrode, water tracks down and stains the chimney face. The liner itself may still be sound, but the failure is often adjacent and progressing.
- Drafting problems on windless days. A liner that has collapsed inward, kinked during a previous poor installation, or lost its round profile to creosote buildup cannot establish proper draft. Boulder sits at 5,430 feet; the thinner air already reduces natural draft compared to sea-level installations, so any liner deformation is magnified.
- Chunks of tile or clay in the firebox. If your chimney was originally clay-lined and the DuraFlex was installed as a retrofit sleeve, tile collapse indicates the original liner has failed and is compromising the stainless sleeve. This is common in pre-1940s Mapleton Hill homes where the original terracotta has spalled from freeze-thaw.
- Camera inspection shows pinholing or “alligator” surface cracking. These are corrosion failure modes in 316Ti stainless when exposed to sustained moisture and acidic flue gas condensate. Boulder’s low humidity actually helps here compared to coastal climates, but improper venting of high-efficiency appliances into a liner sized for wood can still produce condensate that eats the wall.
Before
AfterReplacement Cost & What’s Included
| Component | Typical Range (Boulder) |
|---|---|
| DuraFlex liner (material only), 25-35 ft run | $1,400-$2,200 |
| Top plate, storm collar, termination cap | $280-$450 |
| Connector and adapter fittings | $180-$320 |
| Labor: removal, installation, insulation pack | $940-$1,530 |
| Total installed | $2,800-$4,500 |
What drives the range: chimney height above roofline (a two-story plus exposed chase in Chautauqua runs longer than a ranch cap in Table Mesa), diameter (6-inch is standard; 8-inch for large fireplaces costs disproportionately more), and whether the existing top plate is salvageable. Every quote we deliver in writing under Haven Standard Clause 1 breaks these line items out - no lump-sum mystery. The liner carries a lifetime limited warranty through DuraFlex; our installation workmanship is covered by the 365-Day Done Right Promise. Clause 4 of the Haven Standard requires a photo record on every job, so you’ll receive camera footage of the completed flue before we pack up.
DIY or Call Us?

There’s a safe middle ground here, and then there’s a hard stop. An owner can verify the liner diameter with a tape measure at the cleanout, check the termination cap for visible corrosion, and confirm the model stamp on the collar - all useful information that speeds our quote. What you cannot safely do is drop a liner from the roof. The work involves working at height on a pitched surface, handling a 25-foot coil of stainless that can kink permanently if torqued wrong, and packing the annular space with insulation that must stay dry and uncompressed to maintain its UL listing. A kinked liner is scrap; a liner installed without proper insulation creates a chimney fire pathway. We bring a two-person crew, roof anchors where the pitch exceeds 6:12, and a rigging system that protects both the liner and your flashing. Call (970) 598-0453 and we’ll scope it with the camera first - no charge for the inspection, and you’ll see exactly what we see before any number gets written.
FAQs
A properly installed DuraFlex 316Ti liner in a wood-burning system typically lasts 15-25 years in Boulder’s dry climate, though we’ve seen premature failure at 8-10 years when the liner was paired with an incorrectly vented gas insert or exposed to sustained condensate from an unlined appliance connection. Annual inspection catches the transition before it becomes a safety issue. Call (970) 598-0453 to schedule a camera scan - estimates are free.
Partial repair is viable for isolated damage: HeatShield joint repair can seal a separated seam, and a local patch from Gelco or Copperfield stock can address a single corrosion point if the surrounding wall thickness passes gauge. We do not recommend repair when the camera shows multiple failure points, wall thinning below .003-inch, or any collapse - the labor to access the flue twice exceeds replacement cost. We’ll show you the footage and explain which side of that line your liner sits on. Call (970) 598-0453 for a free second opinion on any written estimate.
Most DuraFlex flue liner replacements in Boulder are completed in one day, typically 4-6 hours of on-site work for a standard single-flue chimney up to 35 feet. Second-story chimneys with steep roof access, or jobs requiring masonry repair to the crown before the new liner can be sealed, may extend to a second day. We book the full day and finish early rather than rush. Call (970) 598-0453 to check availability - we answer live, 24/7.
We stock DuraFlex-compatible flue liner in diameters from 3-inch to 8-inch on our Boulder trucks, along with the full fitting set for SW and HT series terminations. For unusual diameters or the rare 316L specialty run, Haven’s buying network delivers within 48 hours. In sixteen years we’ve never lost a job to parts availability. Call (970) 598-0453 to confirm your diameter and series - we’ll have it on the truck when we arrive.
Written by Corrine Halstead, Owner, Emberly Chimney Cleaners Boulder at Emberly Chimney Cleaners Boulder, serving Boulder and nearby areas.





Before
After
Before
After